| UNH+ME000001+QALITY:D:01B:UN:EAN003' |
Message header |
| BGM+4+45223+9' |
Quality message number 45223 |
| DTM+137:20020615:102' |
Message date 15th June 2002 |
| RFF+TS:52114' |
Test specification number 52114 |
| NAD+OB+5412345123453::9' |
Ordering party identified by GLN 5412345123453 |
| NAD+TPE+++STOCKHOLM METER SERVICES' |
Testing party Stockholm Meter Services |
| CTA+IC+:BJORN NIELSEN' |
Testing party contact person |
| COM+031-13425:TE' |
Telephone number for contact person |
| COM+031-13455:FX' |
Fax number for contact person |
| LIN+1++5412345111115:SRV' |
Identification of the test carried out for the article identified by GTIN
5412345111115 |
| PIA+1+SE-OSC-K135:SA' |
Identification of meter type using supplier allocated number |
| PIA+1+SVM93:MF' |
Identification of the manufacturers article number |
| PIA+1+9216995:SN' |
Identification of meter serial number |
| IMD+F++:::PROTOCOL OF METER:CONTROL DATA' |
Description of the test |
| MEA+SV+AAU+CEL::20:150' |
Specification of operating temperature range in celsius |
| DTM+94:20010212:102' |
Meter manufactured on the 12th of February 2001 |
| QTY+79:17108:MWH' |
Previous meter read 17108 megawatt hours |
| QTY+79:34608:MTQ' |
Previous meter read 34608 cubic metres |
| QTY+74:17119:MWH' |
Latest meter read 17119 megawatt hours |
| QTY+74:34641:MTQ' |
Latest meter read 34641 cubic metres |
| NAD+MF+++SVM' |
Identification of the manufacturer of the meter |
| CCI+TES' |
Indication of start of first test results |
| MEA+MV+TC+CEL::50:50' |
Test measured value in temperature range of 50-50 degrees celsius |
| MEA+TR+ENE+MWH:0.5' |
Test results = energy efficiency of 0.5 megawatt hours |
| CCI+TES' |
Indication of start of second test results |
| MEA+MV+TC+CEL::49:50' |
Test measured value in temperature range of
49-50 degrees celsius |
| MEA+TR+ENE+MWH:47.6' |
Test results = energy efficiency of 47.6 megawatt hours |
| CCI+TES' |
Indication of start of third test results |
| MEA+MV+TC+CEL::70:73' |
Test measured value in temperature range of 70-73 degrees celsius |
| MEA+TR+ENE+MWH:140.8' |
Test results = energy efficiency of 140.8 megawatt hours |
| CCI+TES' |
Indication of start of fourth test results |
| MEA+MV+TC+CEL::60:67' |
Test measured value in temperature range of 60-67 degrees celsius |
| MEA+TR+ENE+MWH:328.9' |
Test results = energy efficiency of 328.9 megawatt hours |
| CCI+TES' |
Indication of start of fifth test results |
| MEA+MV+TC+CEL::60:73' |
Test measured value in temperature range of 60-73 degrees celsius |
| MEA+TR+ENE+MWH:610.8 |
Test results = energy efficiency of 610.8 megawatt hours |
| UNT+37+ME000001' |
Total number of segments in the message equals 37 |